FireEye Network Security Datasheet

Effective protection against cyber breaches for midsize to large organizations

FireEye Network Security is an effective cyber threat protection solution that helps organizations minimize the risk of costly breaches by accurately detecting and immediately stopping advanced, targeted and other evasive attacks hiding in Internet traffic. It facilitates efficient resolution of detected security incidents in minutes with concrete evidence, actionable intelligence and response workflow integration. With FireEye Network Security, organizations are effectively protected against today’s threats whether they exploit Microsoft Windows or Apple OS X operating systems or application vulnerabilities; are directed at the headquarters or branch offices; or are hidden in a large volume of inbound Internet traffic that has to be inspected in real time.

At the core of FireEye Network Security are the Multi-Vector Virtual Execution™ (MVX) and Intelligence-Driven Analysis (IDA) technologies. MVX is a signature-less, dynamic analysis engine that inspects suspicious network traffic to identify attacks that evade traditional signature- and policy-based defenses. IDA is a collection of contextual, dynamic rules engines that detects and blocks malicious activity in real-time and retroactively, based on the latest machine-, attacker- and victim-intelligence. FireEye Network Security also includes intrusion prevention system (IPS) technology to detect common attacks using conventional signature matching.

FireEye Network Security is available in a variety of form factor, deployment and performance options. It is typically placed in the path of Internet traffic behind traditional network security appliances such as next-generation firewalls, IPS and secure web gateways (SWG). FireEye Network Security supplements these solutions by rapidly detecting both known and unknown attacks with high accuracy and a low rate of false positives while facilitating an efficient response to each alert.

nx-family-with-10g

Examples of Integrated Network Security include NX 2550, NX 3500, NX 5500, NX 10450.

fig1-network-security
Figure 1. Typical Configuration - Network Security solutions
CAPABILITIES BENEFITS
DETECTION
Accurate detection of advanced, targeted and other evasive cyber attacks Minimizes risk of costly cyber breaches Minimizes risk of costly cyber breaches
Extensible, modular security architecture Provides investment protection Provides investment protection
Consistent level of protection for multi-OS environments and all Internet access points Creates a strong defense across the entire organization for all types of devices Creates a strong defense across the entire organization for all types of devices
Integrated, distributed, physical, virtual, on-premise and cloud deployment options Offers flexibility to align with organizational preferences and resources Offers flexibility to align with organizational preferences and resources
Multi-vector correlation with Email and Content Security Provides visibility across wider attack surface Provides visibility across wider attack surface
PREVENTION
Immediate blocking of attacks at line rates from 10 Mbps to 8 Gbps Gives real-time protection against evasive attacks Gives real-time protection against evasive attacks
RESPONSE
Low rate of false alerts, riskware categorization and automated IPS alert validation Reduces operational cost of triaging unreliable alerts Reduces operational cost of triaging unreliable alerts
Pivot to investigation and alert validation, endpoint containment and incident response Automates and simplifies security workflows Automates and simplifies security workflows
Execution evidence and actionable threat intelligence with contextual insight Accelerates prioritization and resolution of detected security incidents Accelerates prioritization and resolution of detected security incidents
Scalability from one site to thousands of sites Supports business growth Supports business growth

Technical Advantages

Accurate Threat Detection

FireEye Network Security uses multiple analysis techniques to detect attacks with high accuracy and a low rate of false alerts:

  • Multi-Vector Virtual Execution™ (MVX) engine detects zero-day, multi-flow and other evasive attacks with dynamic, signature-less analysis in a safe, virtual environment. It stops infection and compromise phases of the cyber-attack kill chain by identifying never-before-seen exploits and malware.
  • Intelligence-Driven Analysis (IDA) engines detect and block obfuscated, targeted and other customized attacks with contextual, rule-based analysis from realtime insights gathered on the front lines from millions of MVX verdicts, thousands of hours of incident response experience gathered by Mandiant, a FireEye company and hundreds of iSight threat researchers. It stops infection, compromise and intrusion phases of the cyber-attack kill chain by identifying malicious exploits, malware and command and control (CnC) callbacks. It also extracts and submits suspicious network traffic to the MVX engine for a definitive verdict analysis.
  • Structured Threat Intelligence eXpression (STIX) allows the ingestion of third-party threat intelligence using an industry-standard format to add custom threat indicators into the IDA engines.
Immediate and Resilient Protection

FireEye Network Security offers flexible configuration modes including:

  • Out-of-band monitoring via a TAP/SPAN, inline monitoring or inline active blocking. Inline blocking mode automatically blocks inbound exploits and malware and outbound multi-protocol callbacks. In inline monitoring mode, alerts are generated and organizations decide how to respond to them. In out-of-band prevention mode, FireEye Network Security issues TCP resets for out-of-band blocking of TCP, UDP or HTTP connections.
  • Integration with the FireEye Active Fail Open (AFO) switch to ensure no network interruption.
  • Selected models offer an active high availability (HA) option to provide resilience in case of network or device failures.
Wide Attack Surface Coverage

FireEye Network Security delivers a consistent level of protection for today’s diverse network environments:

  • Support for most common Microsoft Windows and Apple Mac OS X operating systems
  • Analysis of over 140 different file types, including portable executables (PEs), web content, archives, images, Java, Microsoft and Adobe applications and multimedia
  • Execution of suspicious network traffic against thousands of operating system, service pack, application type and application version combinations
Validated and Prioritized Alerts

In addition to detecting genuine attacks, FireEye MVX technology is also used to determine the reliability of alerts detected by conventional signature-matching methods and to identify and prioritize critical threats:

  • Intrusion prevention system (IPS) with MVX engine validation reduces the time required to triage signaturebased detection that is traditionally prone to false alerts
  • Riskware categorization separates genuine breach attempts from undesirable, but less malicious activity (such as adware and spyware) to prioritize alert response
Actionable Threat Insights

Alerts generated by FireEye Network Security include concrete evidence and contextual intelligence to quickly respond to, prioritize and contain a threat:

  • Dynamic Threat Intelligence (DTI) – concrete, real-time, globally-shared data to quickly and proactively stop targeted and newly discovered attacks
  • Advanced Threat Intelligence (ATI) – contextual insights about the attack to accelerate response and prescriptive guidance to contain the threat
Response Workflow Integration

FireEye Network Security can be augmented in several place to automate alert response workflows:

  • FireEye Central Management correlates alerts from both FireEye Network Security and FireEye Email Security for a broader view of an attack and to set blocking rules that prevent the attack from spreading further.
  • FireEye Network Forensics integrates with FireEye Network Security to provide detailed packet captures associated with an alert and enable in-depth investigations.
  • FireEye Endpoint Security identifies, validates and contains compromises detected by FireEye Network Security to simplify containment and remediation of affected endpoints.
Flexible Deployment Options

FireEye Network Security offers various deployment options to match an organization’s needs and budget:

  • Integrated Network Security – standalone, all-in-one hardware appliance with integrated MVX service to secure an Internet access point at a single site. FireEye Network Security is an easy-to-manage, clientless platform that deploys in under 60 minutes. It doesn’t require rules, policies or tuning.
  • Distributed Network Security - extensible appliances with centrally shared MVX service to secure Internet access points within organization:
    • Network Smart Node: physical or virtual appliances that analyze Internet traffic to detect and block malicious traffic and submit suspicious activity over an encrypted connection to the MVX service for definitive verdict analysis
    • MVX Smart Grid: on-premise, centrally located, elastic MVX service that offers transparent scalability, built-in N+1 fault tolerance and automated load balancing
    • FireEye Cloud MVX: FireEye-hosted MVX service subscription that ensures privacy by analyzing traffic on the Network Smart Node. Only suspicious objects are sent over an encrypted connection to the MVX service, where objects revealed as benign are discarded
nx-on-prem-distributed-architecture
Figure 3. Distributed deployment models for Network Security.
fig4-network-security
Figure 4. Modular Components of FireEye Network Security
Form Factor Performance
Integrated Network Security 50 Mbps to 4 Gbps 10 Mbps to 4 Gbps
Physical Network Smart Node 50 Mbps to 8 Gbps 20 Mbps to 8 Gbps
Virtual Network Smart Node 50 Mbps to 1 Gbps 50 Mbps to 1 Gbps

The MVX Smart Grid and FireEye Cloud MVX scalable architecture allows the MVX service to support one Network Smart Node to thousands and scale seamlessly as needed.

Extensible Architecture

FireEye Network Smart Nodes feature a modular and extensible software architecture and system design to deliver multiple threat protection capabilities as software modules.

High Performance and Scalability

FireEye Network Security protects Internet access points at line rate with performance options for a wide variety of branch and central office sizes:

Business Benefits

Designed to meet the needs of single-site and distributed multi-site organizations, FireEye Network Security delivers several benefits:

Minimizes Risk of Cyber Breaches

FireEye Network Security is a highly-effective cyber defense solution that:

  • Prevents intruders from breaking into an organization to steal valuable assets or disrupt business by stopping advanced, targeted and other evasive attacks.
  • Stops attacks and contains intrusions faster with concrete evidence, actionable intelligence, inline blocking and response workflow automation.
  • Eliminates weak points from an organization’s cyber defenses with consistent protection for various operating systems, application types, branches and central sites.
Short Payback Period

According to a recent Forrester Consulting study,1 FireEye Network Security customers can expect a 152% ROI savings over three years and payback on their initial investment in just 9.7 months. FireEye Network Security:

  • Focuses security team resources on real attacks to reduce operational expenses
  • Optimizes capital spend with a shared MVX service and a large variety of performance points to rightsize deployment to meet requirements
  • Future-proofs security investment by scaling smoothly when the number of branches or the amount of Internet traffic grows

 

1 Forrester (May 2016). The Total Economic Impact Of FireEye.
2
Frost & Sullivan (October 2016). Network Security Sandbox Market Analysis



  • Protects existing investments by allowing cost-free migration from an integrated to a distributed deployment
  • Reduces future capital outlay with modular and extensible architecture
Awards and Certifications

The FireEye Network Security product portfolio has been awarded a number of industry and government awards and certifications:

  • In 2016, Frost & Sullivan recognized FireEye as the undisputed market leader with 56% market share, more than the next ten competitors combined2
  • FireEye Network Security has been a recipient of numerous awards from SANS Institute, SC Magazine, CRN and others
  • FireEye Network Security was the first security solution on the market to receive the US Department of Homeland Security SAFETY Act Certification

FireEye Network Security (NX)
Achieves 99% Detection Rate

Read results of the independent Delta Testing report comparing leading vendors in the advanced threat protection market.

Download Report 

FireEye Network Security (NX)
Visio Stencils

Use the FireEye NX Visio stencils to plan your data center.

Download Stencils 


Technical Specifications

FireEye Network Security Specifications, Integrated Appliance

NX 2500 NX 2550 NX 3500 NX 4500 NX 5500 NX 10450 NX 10550
User Count User Count 500 or 1,000500 or 1,000 3,0003,000 5,0005,000 10,00010,000 25,00025,000 40,00040,000 40,00040,000
OS SupportOS Support Microsoft Windows
Mac OS X
Microsoft Windows
Mac OS X
Microsoft Windows
Mac OS X
Microsoft Windows
Mac OS X
Microsoft Windows
Mac OS X
Microsoft Windows
Mac OS X
Microsoft Windows
Mac OS X
Microsoft Windows
Mac OS X
Microsoft Windows
Mac OS X
Microsoft Windows
Mac OS X
Microsoft Windows Microsoft Windows Microsoft Windows
Mac OS X
Microsoft Windows
Mac OS X
Performance* Performance* Up to 50 Mbps or 100 Mbps Up to 50 Mbps or 100 Mbps Up to 250 Mbps Up to 250 Mbps Up to 500 Mbps Up to 500 Mbps Up to 1 Gbps Up to 1 Gbps Up to 2.5 Gbps Up to 2.5 Gbps Up to 4 Gbps Up to 4 Gbps Up to 4 Gbps Up to 4 Gbps
Network Monitoring PortsNetwork Monitoring Ports 4x 10/100/1000 BASE-T Ports (in front panel)4x 10/100/1000 BASE-T Ports (in front panel) 4x 10Gig E SFP+ 4x 1Gig E Bypass4x 10GigE SFP+ 4x 1Gig E Bypass 4x 10Gig E SFP+ 4x 1Gig E Bypass4x 10GigE SFP+ 4x 1Gig E Bypass 2x 4x 10Gig E SFP+ 4x 1Gig E Bypass2x 4x 10GigE SFP+ 4x 1Gig E Bypass 2x 4x 10Gig E SFP+ 4x 1Gig E Bypass2x 4x 10GigE SFP+ 4x 1Gig E Bypass 8 x SFP+ (4 x 1000 base and 4x10 GBASE), 1000 base SX / 10 GBASE SR (LC, MMF), 1000 baseLX / 10 GBASE LR (LC SMF), 1000 baseT (RJ45, UTP5), 10 GBASECu (5m direct attached cable)8 x SFP+ (4 x 1000 base and 4x10 GBASE), 1000 base SX / 10 GBASE SR (LC, MMF), 1000 baseLX / 10 GBASE LR (LC SMF), 1000 baseT (RJ45, UTP5), 10 GBASECu (5m direct attached cable) 8 x SFP+ (4 x 1000 base and 4x10 GBASE), 1000 base SX / 10 GBASE SR (LC, MMF), 1000 baseLX/ 10 GBASE LR (LC SMF), 1000 baseT (RJ45, UTP5), 10 GBASECu (5m direct attached cable)8 x SFP+ (4 x 1000 base and 4x10 GBASE), 1000 base SX / 10 GBASE SR (LC, MMF), 1000 baseLX / 10 GBASE LR (LC SMF), 1000 baseT (RJ45, UTP5), 10 GBASECu (5m direct attached cable)
High Availability (HA) High Availability (HA) Not Available Not Available Not Available Not Available Not Available Not Available Not Available Not Available Not Available Not Available Active-Passive HA Active-Passive HA Active-Passive HA Active-Passive HA
Network Ports Mode of OperationNetwork Ports Mode of Operation In-line Monitor, Fail-Open, Fail- Close, or Tap/ Span, HW BypassIn-line Monitor, Fail-Open, Fail- Close, or Tap/ Span, HW Bypass Inline Monitor, Fail-Open, Fail-Close, or Tap/Span, HW BypassInline Monitor, Fail-Open, Fail-Close, or Tap/Span, HW Bypass/span> Inline Monitor, Fail-Open, Fail-Close, or Tap/Span, HW BypassInline Monitor, Fail-Open, Fail-Close, or Tap/Span, HW Bypass Inline Monitor, Fail-Open, Fail-Close, or Tap/Span, HWInline Monitor, Fail-Open, Fail-Close, or Tap/Span, HW Inline Monitor, Fail-Open, Fail-Close, or Tap/Span, HW BypassInline Monitor, Fail-Open, Fail-Close, or Tap/Span, HW Bypass Inline Monitor, or Tap/SpanInline Monitor, or Tap/Span Inline Monitor, or Tap/SpanInline Monitor, or Tap/Span
High Availability (HA) Ports (rear panel) High Availability (HA) Ports (rear panel) Not Available Not Available Not Available Not Available Not Available Not Available Not Available Not Available 2 x 100/1000/10G Base-T Ports 2 x 100/1000/10G Base-T Ports 2 x 100/1000/10G Base-T Ports 2 x 100/1000/10G Base-T Ports 2 x 100/1000/10G Base-T Ports 2 x 100/1000/10G Base-T Ports
Management Ports (rear panel)Management Ports (rear panel) 2x 10/100/1000 BASE- T Ports (in front panel)2x 10/100/1000 BASE- T Ports (in front panel) 2x 10/ 100/1000 BASE-T Ports2x 10/ 100/1000 BASE-T Ports 2x 10/ 100/1000 BASE-T Ports2x 10/ 100/1000 BASE-T Ports 2x 10/ 100/1000 BASE-T Ports2x 10/ 100/1000 BASE-T Ports 2x 10/ 100/1000 BASE-T Ports2x 10/ 100/1000 BASE-T Ports 2x 10/ 100/1000 BASE-T Ports2x 10/ 100/1000 BASE-T Ports 2x 10/ 100/1000 BASE-T Ports2x 10/ 100/1000 BASE-T Ports
IPMI MonitoringIPMI Monitoring IncludedIncluded IncludedIncluded IncludedIncluded IncludedIncluded IncludedIncluded IncludedIncluded IncludedIncluded
Front LCD & KeypadFront LCD & Keypad Not AvailableIncluded Not AvailableIncluded Not AvailableIncluded Not AvailableIncluded Not AvailableIncluded IncludedIncluded IncludedIncluded
PS/2 Keyboard and Mouse, DB15 VGA Ports (rear panel) PS/2 Keyboard and Mouse, DB15 VGA Ports (rear panel) Not AvailableIncluded VGA port IncludedVGA port Included VGA port IncludedVGA port Included VGA port IncludedVGA port Included VGA port IncludedVGA port Included IncludedIncluded Included (no PS/2 Keyboard and Mouse)Included (no PS/2 Keyboard and Mouse)
USB Ports (rear panel) USB Ports (rear panel) 2x Type A USB Ports (front panel)2x Type A USB Ports (front panel) 2x Type A USB Ports2x Type A USB Ports 2x Type A USB Ports2x Type A USB Ports 2x Type A USB Ports2x Type A USB Ports 2x Type A USB Ports2x Type A USB Ports 2x Type A USB Ports2x Type A USB Ports 2x Type A USB Ports2x Type A USB Ports
Serial Port (rear panel)Serial Port (rear panel) 115,200 bps, No Parity, 8 Bits, 1 Stop Bit (RJ45 connector RJ45- to-Dsub adapter cable is included)115,200 bps, No Parity, 8 Bits, 1 Stop Bit (RJ45 connector RJ45- to-Dsub adapter cable is included) 115,200 bps, No Parity, 8 Bits, 1 Stop Bit115,200 bps, No Parity, 8 Bits, 1 Stop Bit 115,200 bps, No Parity, 8 Bits, 1 Stop Bit115,200 bps, No Parity, 8 Bits, 1 Stop Bit 115,200 bps, No Parity, 8 Bits, 1 Stop Bit115,200 bps, No Parity, 8 Bits, 1 Stop Bit 115,200 bps, No Parity, 8 Bits, 1 Stop Bit115,200 bps, No Parity, 8 Bits, 1 Stop Bit 115,200 bps, No Parity, 8 Bits, 1 Stop Bit115,200 bps, No Parity, 8 Bits, 1 Stop Bit 115,200 bps, No Parity, 8 Bits, 1 Stop Bit115,200 bps, No Parity, 8 Bits, 1 Stop Bit
Drive CapacityDrive Capacity Single 1TB 3.5 inch, SATA HDD, internal, fixedSingle 1TB 3.5 inch, SATA HDD, internal, fixed 4 TB 2 x 4TB HDD, 3.5", SAS3, 7.2krpm, RAID14 TB 2 x 4TB HDD, 3.5", SAS3, 7.2krpm, RAID1 4 TB 2 x 4TB HDD, 3.5", SAS3, 7.2krpm, RAID14 TB 2 x 4TB HDD, 3.5", SAS3, 7.2krpm, RAID1 4 TB 2 x 4TB HDD, 3.5", SAS3, 7.2krpm, RAID14 TB 2 x 4TB HDD, 3.5", SAS3, 7.2krpm, RAID1 4 TB 2 x 4TB HDD, 3.5", SAS3, 7.2krpm, RAID14 TB 2 x 4TB HDD, 3.5", SAS3, 7.2krpm, RAID1 4x 800 GB SSD, RAID 10, 2.5 inch, FRU4x 800 GB SSD, RAID 10, 2.5 inch, FRU 4x 960 GB SSD, RAID 10, 2.5 inch, FRU4x 960 GB SSD, RAID 10, 2.5 inch, FRU
EnclosureEnclosure 1RU, Fits 19 inch Rack1RU, Fits 19 inch Rack 1RU, Fits 19 inch Rack1RU, Fits 19 inch Rack 2RU, Fits 19 inch Rack2RU, Fits 19 inch Rack 2RU, Fits 19 inch Rack2RU, Fits 19 inch Rack 2RU, Fits 19 inch Rack2RU, Fits 19 inch Rack 2RU, Fits 19 inch Rack2RU, Fits 19 inch Rack 2RU, Fits 19 inch Rack2RU, Fits 19 inch Rack
Chassis Dimension WxDxHChassis Dimension WxDxH 17.2in(437mm) x 19.7in(500mm) x 1.7in(43.2 mm)>17.2in (437mm) x 19.7in (500mm) x 1.7in (43.2 mm) 17.2in (437mm) x 25.6in (650mm) x 1.7in(43.2mm)17.2in (437mm) x 25.6in (650mm) x 1.7in(43.2mm) 17.24in (438mm) x 24.41in (620mm) x 3.48in (88.4mm)17.24in (438mm) x 24.41in (620mm) x 3.48in (88.4mm) 17.24in (438mm) x 24.41in (620mm) x 3.48in (88.4mm)17.24in (438mm) x 24.41in (620mm) x 3.48in (88.4mm) 17.24in (438mm) x 24.41in (620mm) x 3.48in (88.4mm)17.24in (438mm) x 24.41in (620mm) x 3.48in (88.4mm) 17.2in (437mm) x 27.9in (709mm) x 3.5in (89mm)17.2in (437mm) x 27.9in (709mm) x 3.5in (89mm) 17.2in (437mm) x 33.5in (851mm) x 3.5in (89mm)17.2in (437mm) x 33.5in (851mm) x 3.5in (89mm)
AC Power SupplyAC Power Supply Single 250 watt, 90-264 VAC, 3.5 - 1.5 A, 50-60 Hz, IEC60320-C14, inlet,Internal, FixedSingle 250 watt, 90-264 VAC, 3.5 - 1.5 A, 50-60 Hz, IEC60320-C14, inlet,Internal, Fixed Redundant (1+1) 750 watt,100 - 240 VAC 9 – 4.5A, 50-60 Hz IEC60320 -C14 inlet, FRUeRedundant (1+1) 750 watt,100 - 240 VAC 9 – 4.5A, 50-60 Hz IEC60320 -C14 inlet, FRU Redundant (1+1) 800 watt, 100 - 240 VAC 10.5 – 4.0A, 50-60 Hz IEC60320-C14 inlet, FRURedundant (1+1) 800 watt, 100 - 240 VAC 10.5 – 4.0A, 50-60 Hz IEC60320-C14 inlet, FRU Redundant (1+1) 800 watt, 100 - 240 VAC 10.5 – 4.0A, 50-60 Hz IEC60320-C14 inlet, FRURedundant (1+1) 800 watt, 100 - 240 VAC 10.5 – 4.0A, 50-60 Hz IEC60320-C14 inlet, FRU Redundant (1+1) 800 watt, 100 - 240 VAC 10.5 – 4.0A, 50-60 Hz IEC60320-C14 inlet, FRURedundant (1+1) 800 watt, 100 - 240 VAC 10.5 – 4.0A, 50-60 Hz IEC60320-C14 inlet, FRU Redundant (1+1) 1200 watt, 100 - 140 VAC, 14.7 - 10.5 A 1400 watt, 180 - 240 VAC, 9.5 - 7.2 A, 50-60 Hz, FRU IEC60320 -C14 inlet, FRURedundant (1+1) 1200 watt, 100 - 140 VAC, 14.7 - 10.5 A 1400 watt, 180 - 240 VAC, 9.5 - 7.2 A, 50-60 Hz, FRU IEC60320 -C14 inlet, FRU Redundant (1+1) 800W: 100-127V, 9.8A-7A 1000W: 220-240V, 7-5A, 50-60Hz, FRU IEC60320-C14 inlet, FRURedundant (1+1) 800W: 100-127V, 9.8A-7A 1000W: 220-240V, 7-5A, 50-60Hz, FRU IEC60320-C14 inlet, FRU
Power Consumption Maximum (watts)Power Consumption Maximum (watts) 85 watts85 watts 265 watts265 watts 426 watts426 watts 519 watts519 watts 658 watts658 watts 850 watts850 watts 760 watts760 watts
Thermal Dissipation Maximum (BTU/h)hermal Dissipation Maximum (BTU/h) 290 BTU/h290 BTU/h 904 BTU/h904 BTU/h 1,454 BTU/h1,454 BTU/h 1,771 BTU/h1,771 BTU/h 2,245 BTU/h2,245 BTU/h 2908 BTU/h2908 BTU/h 2594 BTU/h2594 BTU/h
MTBF(h)MTBF(h) 56,400 h56,400 h 54,200 h54,200 h 31,640 h31,640 h 20,010 h20,010 h 11,870 h11,870 h 40,275 h40,275 h 36,101 h36,101 h
Appliance Alone / As Shipped Weight lb.(kg)Appliance Alone / As Shipped Weight lb.(kg) 16.2 lb (7.3 kg) / 28.2 lb (2.95 kg)16.2 lb (7.3 kg) / 28.2 lb (2.95 kg) 29.8 lbs (13.5 Kg) / 40.8 lbs (18.5 Kg)29.8 lbs (13.5 Kg) / 40.8 lbs (18.5 Kg) 37.4 lbs (17.0 Kg) / 58.6 lbs (26.6 kg)37.4 lbs (17.0 Kg) / 58.6 lbs (26.6 kg) 42.4 lbs (19.2 Kg) / 63.5 lbs (28.8 kg)42.4 lbs (19.2 Kg) / 63.5 lbs (28.8 kg) 42.7 lbs (19.2 Kg) / 63.8 lbs (29.0 kg)42.7 lbs (19.2 Kg) / 63.8 lbs (29.0 kg) 51 lb. (23 kg) / 66 lb. (30 kg)51 lb. (23 kg) / 66 lb. (30 kg) 46 lb (21 kg) / 90 lb (40.2 kg)46 lb (21 kg) / 90 lb (40.2 kg)
Regulatory Compliance SafetyRegulatory Compliance Safety EN 60950-1, 1:2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013; IEC 60950 - 1:2005 + Am 1:2009 + Am 2:2013EN 60950-1, 1:2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013; IEC 60950-1:2005 + Am 1:2009 + Am 2:2013 IEC 60950-1:2005 (Second Edition) + Am1:2009 + Am 2:2013 EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013 CSA 60950-1-07, Second Edition CAN/CSA-C22.2 No 60950-1-07 + Am1:2011 + Am2:2014IEC 60950-1:2005 (Second Edition) + Am1:2009 + Am 2:2013 EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013 CSA 60950-1-07, Second Edition CAN/CSA-C22.2 No 60950-1-07 + Am1:2011 + Am2:2014 IEC 60950-1:2005 (Second Edition) + Am1:2009 + Am 2:2013 EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013 UL 60950 CAN/CSA-C22.2 No 60950-1-07, + Am.1:2011 + Am.2:2014 Information Technology Equipment - Safety - Part 1: General Requirements UL 60950-1-2014IEC 60950-1:2005 (Second Edition) + Am1:2009 + Am 2:2013 EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013 UL 60950 CAN/CSA-C22.2 No 60950-1-07, + Am.1:2011 + Am.2:2014 Information Technology Equipment - Safety - Part 1: General Requirements UL 60950-1-2014 IEC 60950-1:2005 (Second Edition) + Am1:2009 + Am 2:2013 EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013 UL 60950 CAN/CSA-C22.2 No 60950-1-07, + Am.1:2011 + Am.2:2014 Information Technology Equipment - Safety - Part 1: General Requirements UL 60950-1-2014IEC 60950-1:2005 (Second Edition) + Am1:2009 + Am 2:2013 EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013 UL 60950 CAN/CSA-C22.2 No 60950-1-07, + Am.1:2011 + Am.2:2014 Information Technology Equipment - Safety - Part 1: General Requirements UL 60950-1-2014 IEC 60950-1:2005 (Second Edition) + Am1:2009 + Am 2:2013 EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013 UL 60950 CAN/CSA-C22.2 No 60950-1-07, + Am.1:2011 + Am.2:2014 Information Technology Equipment - Safety - Part 1: General Requirements UL 60950-1-2014IEC 60950-1:2005 (Second Edition) + Am1:2009 + Am 2:2013 EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013 UL 60950 CAN/CSA-C22.2 No 60950-1-07, + Am.1:2011 + Am.2:2014 Information Technology Equipment - Safety - Part 1: General Requirements UL 60950-1-2014 IEC 60950-1 EN 60950-1 CSA 60950-1 CE MarkingIEC 60950-1 EN 60950-1 CSA 60950-1 CE Marking UL 60950-1, CAN/ CSA C22.2 No. 60950-1-07, IEC 60950- 1:2005 + A1:2009 + A2:2013, AS/NSZ 60950.1-2011UL 60950-1, CAN/ CSA C22.2 No. 60950-1-07, IEC 60950- 1:2005 + A1:2009 + A2:2013, AS/NSZ 60950.1-2011
Regulatory Compliance EMCRegulatory Compliance EMC FCC Part 15 SubPart B Class A; ICES-003 Class A; EN55022 Class A; VCCI V-3 Class A; EN 55024, EN 61000-3-2 Class A; EN 61000-3-3; CNS 13438 (2006) Class A; CISPR22 Class A; AS/NZS CISPR 22 Class A; KN 32; KN 35FCC Part 15 SubPart B Class A; ICES-003 Class A; EN55022 Class A; VCCI V-3 Class A; EN 55024, EN 61000-3-2 Class A; EN 61000-3-3; CNS 13438 (2006) Class A; CISPR22 Class A; AS/NZS CISPR 22 Class A; KN 32; KN 35 FCC Part 15 SubPart B Class A; ICES-003 Class A; EN55022 Class A; VCCI V-3 Class A; EN 55024; EN 61000-3-2 Class A; EN 61000-3-3; CNS 13438 (2006) Class A; CISPR22 Class A; AS/NZS CISPR 22 Class A; KN 32; KN 35FCC Part 15 SubPart B Class A; ICES-003 Class A; EN55022 Class A; VCCI V-3 Class A; EN 55024; EN 61000-3-2 Class A; EN 61000-3-3; CNS 13438 (2006) Class A; CISPR22 Class A; AS/NZS CISPR 22 Class A; KN 32; KN 35FCC (Part 15 Class-A), CE (Class-A), CNS, AS/NZS, VCCI(Class A) FCC Part 15 SubPart B Class A; ICES-003 Class A; EN 61000-3-2 Class A; EN 61000-3-3; CISPR22 Class A;FCC Part 15 SubPart B Class A; ICES-003 Class A; EN 61000-3-2 Class A; EN 61000-3-3; CISPR22 Class A; FCC Part 15 SubPart B Class A; ICES-003 Class A; EN 61000-3-2 Class A; EN 61000-3-3; CISPR22 Class A;FCC Part 15 SubPart B Class A; ICES-003 Class A; EN 61000-3-2 Class A; EN 61000-3-3; CISPR22 Class A; FCC Part 15 SubPart B Class A; ICES-003 Class A; EN 61000-3-2 Class A; EN 61000-3-3; CISPR22 Class A;FCC Part 15 SubPart B Class A; ICES-003 Class A; EN 61000-3-2 Class A; EN 61000-3-3; CISPR22 Class A; FCC (Part 15 Class-A), CE (Class-A), CNS, AS/NZS, VCCI(Class A)FCC (Part 15 Class-A), CE (Class-A), CNS, AS/NZS, VCCI(Class A)> FCC Part 15SubPart B Class A, ICES-003 Class A, EN55022 Class A, VCCI V-3 Class A,EN 55024, EN61000-3-2 Class A, EN 61000-3-3, CNS 13438 (2006) Class A, CISPR22 Class A, AS/NZS CISPR 22 Class AFCC Part 15SubPart B Class A, ICES-003 Class A, EN55022 Class A, VCCI V-3 Class A,EN 55024, EN61000-3-2 Class A, EN 61000-3-3, CNS 13438 (2006) Class A, CISPR22 Class A, AS/NZS CISPR 22 Class A
Safety CertificationsSafety Certifications (none)(none) (none)(none) (none)(none) (none)(none) (none)(none) CC NDPP v1.1CC NDPP v1.1 UL 60950-1,CAN/CSA C22.2 No. 60950-1-07, IEC6060950-1:2005 +A1:2009+ A2:2013, AS/NSZ 60950.1-2011UL 60950-1,CAN/CSA C22.2 No. 60950-1-07, IEC6060950-1:2005 +A1:2009+ A2:2013, AS/NSZ 60950.1-2011
Environmental ComplianceRegulatory Compliance RoHS, REACH, WEEERoHS, REACH, WEEE RoHS, REACH, WEEERoHS, REACH, WEEE RoHS, REACH, WEEERoHS, REACH, WEEE RoHS, REACH, WEEERoHS, REACH, WEEE RoHS, REACH, WEEERoHS, REACH, WEEE RoHS, REACH, WEEERoHS, REACH, WEEE RoHS, REACH, WEEERoHS, REACH, WEEE
Operating TemperatureOperating Temperature 0° C to 40° C0° C to 40° C 0 ~ 35° C, 32 ~ 95° F0 ~ 35° C, 32 ~ 95° F 0 ~ 35° C, 32 ~ 95° F0 ~ 35° C, 32 ~ 95° F 0 ~ 35° C, 32 ~ 95° F0 ~ 35° C, 32 ~ 95° F 0 ~ 35° C, 32 ~ 95° F0 ~ 35° C, 32 ~ 95° F 10°C to 35°C Tested from 0°C to 40°C for additional margin10°C to 35°C Tested from 0°C to 40°C for additional margin 10°C to 35°C Tested from 0°C to 40°C for additional margin10°C to 35°C Tested from 0°C to 40°C for additional margin
Non-Operating TemperatureNon-Operating Temperature -20°C to 80°C-20°C to 80°C -40 ~ 70° C, -40 ~ 158° F-40 ~ 70° C, -40 ~ 158° F -40 ~ 70° C, -40 ~ 158° F-40 ~ 70° C, -40 ~ 158° F -40 ~ 70° C, -40 ~ 158° F-40 ~ 70° C, -40 ~ 158° F -40 ~ 70° C, -40 ~ 158° F-40 ~ 70° C, -40 ~ 158° F -40°C to 70°C-40°C to 70°C -40°C to 70°C-40°C to 70°C
Operating Relative HumidityOperating Relative Humidity 5% - 85% (non-condensing)5% - 85% (non-condensing) 8% - 90% (non-condensing)8% - 90% (non-condensing) 8% - 90% (non-condensing)8% - 90% (non-condensing) 8% - 90% (non-condensing)8% - 90% (non-condensing) 10% - 85% (non-condensing)10% - 85% (non-condensing) 10% - 85% (non-condensing)10% - 85% (non-condensing) 10% - 85% (non-condensing)10% - 85% (non-condensing)
Non- Operating Relative HumidityNon- Operating Relative Humidity 5% - 85% (non-condensing)5% - 85% (non-condensing) 10 ~ 95% @ 40° C, non-condensing10 ~ 95% @ 40° C, non-condensing 10 ~ 95% @ 40° C, non-condensing10 ~ 95% @ 40° C, non-condensing 10 ~ 95% @ 40° C, non-condensing10 ~ 95% @ 40° C, non-condensing 10 ~ 95% @ 40° C, non-condensing10 ~ 95% @ 40° C, non-condensing 5% - 95% (non-condensing)5% - 95% (non-condensing) 5% - 95% (non-condensing)5% - 95% (non-condensing)
Operating AltitudeOperating Altitude 5.000 ft5.000 ft 5.000 ft5.000 ft 5.000 ft5.000 ft 5.000 ft5.000 ft 5.000 ft5.000 ft 5.000 ft5.000 ft 5.000 ft5.000 ft

FireEye Network Security IPS Specifications, Integrated Appliance

NX 2500 NX 2550 NX 3500 NX 4500 NX 5500 NX 10450 NX 10550
Max IPS PerformanceMax IPS Performance Up to 50 Mbps or 100 MbpsUp to 50 Mbps or 100 Mbps 250 Mbps250 Mbps Up to 500 GbpsUp to 500 Gbps Up to 1 GbpsUp to 1 Gbps Up to 2.5 GbpsUp to 2.5 Gbps Up to 4 GbpsUp to 4 Gbps Up to 4 GbpsUp to 4 Gbps
Max Concurrent Connections Max Concurrent Connections 15K or 80K 15K or 80K 80K 80K 160K 160K 500K 500K 1M 1M 2M 2M 2M 2M
New Connections Per SecondNew Connections Per Second 750/Sec or 4K/Sec750/Sec or 4K/Sec 4K/Sec4K/Sec 8K/Sec8K/Sec 10K/Sec10K/Sec 20K/Sec20K/Sec 40K/Sec40K/Sec 40K/Sec40K/Sec

FireEye Network Security Smart Node, Physical Specifications

NX 1500 NX 2500 NX 2550 NX 3500 NX 4500 NX 5500 NX 10450 NX 10550
User Count User Count 500500 1,000 or 2,5001,000 or 2,500 6,0006,000 10,00010,000 20,00020,000 50,00050,000 80,00080,000 80,00080,000
OS SupportOS Support Microsoft Windows Mac OS X Microsoft Windows Mac OS X Microsoft Windows Mac OS X Microsoft Windows Mac OS X Microsoft Windows Mac OS X Microsoft Windows Mac OS X Microsoft Windows Mac OS X Microsoft Windows Mac OS X Microsoft Windows MAC OSX Microsoft Windows MAC OSX Microsoft Windows Mac OS X Microsoft Windows Mac OS X Microsoft Windows Mac OS X Microsoft Windows Mac OS X Microsoft Windows MacOS X Microsoft Windows MacOS X
Performance* Performance* Up to 50 Up to 50 Up to 100 Mbps or 250 Mbps Up to 100 Mbps or 250 Mbps Up to 500 Mbps Up to 500 Mbps Up to 1 Gbps Up to 1 Gbps Up to 2 Gbps Up to 2 Gbps Up to 5 Gbps Up to 4 Gbps Up to 8 Gbps Up to 8 Gbps Up to 8 Gbps Up to 8 Gbps
Network Monitoring PortsNetwork Monitoring Ports 4x 10/100/1000 BASE-T Ports 4x 10/100/1000 BASE-T Ports 4x 10/100/1000 BASE-T Ports (in front panel)4x 10/100/1000 BASE-T Ports (in front panel) 4x 10GigE SFP+ 4x 1GigE Bypass4x 10GigE SFP+ 4x 1GigE Bypass 4x 10GigE SFP+ 4x 1GigE Bypass4x 10GigE SFP+ 4x 1GigE Bypass 2x 4x 10GigE SFP+ 4x 1GigE Bypass2x 4x 10GigE SFP+ 4x 1GigE Bypass 2x 4x 10GigE SFP+ 4x 1GigE Bypass2x 4x 10GigE SFP+ 4x 1GigE Bypass 8 x SFP+ (4 x 1000 base and 4x10 GBASE), 1000 base SX / 10 GBASE SR (LC, MMF), 1000 baseLX/ 10 GBASE LR (LC SMF), 1000 baseT (RJ45, UTP5), 10 GBASECu (5m direct attached cable)8 x SFP+ (4 x 1000 base and 4x10 GBASE), 1000 base SX / 10 GBASE SR (LC, MMF), 1000 baseLX / 10 GBASE LR (LC SMF), 1000 baseT (RJ45, UTP5), 10 GBASECu (5m direct attached cable) 8 x SFP+ (4 x 1000 base and 4x10 GBASE), 1000 base SX / 10 GBASE SR (LC, MMF), 1000 baseLX/ 10 GBASE LR (LC SMF), 1000 baseT (RJ45, UTP5), 10 GBASECu (5m direct attached cable)8 x SFP+ (4 x 1000 base and 4x10 GBASE), 1000 base SX / 10 GBASE SR (LC, MMF), 1000 baseLX / 10 GBASE LR (LC SMF), 1000 baseT (RJ45, UTP5), 10 GBASECu (5m direct attached cable)
High Availability (HA) High Availability (HA) Not Available Not Available Not Available Not Available Not Available Not Available Not Available Not Available Not Available Not Available Active-Passive HA Active-Passive HA Active-Passive HA Active-Passive HA Active-Passive HA Active-Passive HA
Network Ports Mode of OperationNetwork Ports Mode of Operation In-line Monitor, Fail- Close or TapInline Monitor, Fail-Open, Fail-Close, or Tap/Span, HW Bypass Inline Monitor, Fail-Open, Fail-Close, or Tap/Span, HW BypassInline Monitor, Fail-Open, Fail-Close, or Tap/Span, HW Bypass/span> Inline Monitor, Fail-Open, Fail-Close, or Tap/Span, HW BypassInline Monitor, Fail-Open, Fail-Close, or Tap/Span, HW Bypass/span> Inline Monitor, Fail-Open, Fail-Close, or Tap/Span, HW BypassInline Monitor, Fail-Open, Fail-Close, or Tap/Span, HW Bypass Inline Monitor, Fail-Open, Fail-Close, or Tap/Span, HWInline Monitor, Fail-Open, Fail-Close, or Tap/Span, HW In-line Monitor; TAP; or SPANInline Monitor, or Tap, or SPAN In-line Monitor; TAP; or SPANIn-line Monitor; TAP; or SPAN In-line Monitor; TAP; or SPANIn-line Monitor; TAP; or SPAN
High Availability (HA) Ports (rear panel) High Availability (HA) Ports (rear panel) Not Available Not Available Not Available Not Available Not Available Not Available Not Available Not Available Not Available Not Available 2 x 100/1000/10G Base-T Ports 2 x 100/1000/10G Base-T Ports 2 x 100/1000/10G Base-T Ports 2 x 100/1000/10G Base-T Ports 2 x 100/1000/10G Base-T Ports 2 x 100/1000/10G Base-T Ports
Management Ports (rear panel)Management Ports (rear panel) 2x 10/100/1000 BASE- T Ports2x 10/100/1000 BASE- T Ports 2x 10/100/1000 BASE- T Ports (in front panel)2x 10/100/1000 BASE- T Ports (in front panel) 2x 10/ 100/1000 BASE-T Ports2x 10/ 100/1000 BASE-T Ports 2x 10/ 100/1000 BASE-T Ports2x 10/ 100/1000 BASE-T Ports 2x 10/ 100/1000 BASE-T Ports2x 10/ 100/1000 BASE-T Ports 2x 10/ 100/1000 BASE-T Ports2x 10/ 100/1000 BASE-T Ports 2x 10/ 100/1000 BASE-T Ports2x 10/ 100/1000 BASE-T Ports 2x 10/ 100/1000 BASE-T Ports2x 10/ 100/1000 BASE-T Ports
IPMI MonitoringIPMI Monitoring Not AvailableNot Available IncludedIncluded IncludedIncluded IncludedIncluded IncludedIncluded IncludedIncluded IncludedIncluded IncludedIncluded
Front LCD & KeypadFront LCD & Keypad Not AvailableIncluded Not AvailableIncluded IncludedIncluded IncludedIncluded IncludedIncluded IncludedIncluded IncludedIncluded IncludedIncluded
PS/2 Keyboard and Mouse, DB15 VGA Ports (rear panel) PS/2 Keyboard and Mouse, DB15 VGA Ports (rear panel) Not AvailableIncluded Not AvailableIncluded IncludedIncluded IncludedIncluded Included (no PS/2 Keyboard and Mouse)Included (no PS/2 Keyboard and Mouse) IncludedIncluded IncludedIncluded Included (no PS/2 Keyboard and Mouse)Included (no PS/2 Keyboard and Mouse)
USB Ports (rear panel) USB Ports (rear panel) 2x Type A USB Ports2x Type A USB Ports 2x Type A USB Ports (front panel)2x Type A USB Ports (front panel) 2x Type A USB Ports2x Type A USB Ports 2x Type A USB Ports2x Type A USB Ports 4x Type A USB Ports4x Type A USB Ports 2x Type A USB Ports2x Type A USB Ports 2x Type A USB Ports2x Type A USB Ports 2x Type A USB Ports2x Type A USB Ports
Serial Port (rear panel)Serial Port (rear panel) 115,200 bps, No Parity, 8 Bits, 1 Stop Bit (RJ45 connector RJ45- to -Dsub adapter cable is included)115,200 bps, No Parity, 8 Bits, 1 Stop Bit (RJ45 connector RJ45- to -Dsub adapter cable is included) 115,200 bps, No Parity, 8 Bits, 1 Stop Bit (RJ45 connector RJ45- to -Dsub adapter cable is included)115,200 bps, No Parity, 8 Bits, 1 Stop Bit (RJ45 connector RJ45- to- Dsub adapter cable is included) 115,200 bps, No Parity, 8 Bits, 1 Stop Bit115,200 bps, No Parity, 8 Bits, 1 Stop Bit 115,200 bps, No Parity, 8 Bits, 1 Stop Bit115,200 bps, No Parity, 8 Bits, 1 Stop Bit 115,200 bps, No Parity, 8 Bits, 1 Stop Bit115,200 bps, No Parity, 8 Bits, 1 Stop Bit 115,200 bps, No Parity, 8 Bits, 1 Stop Bit115,200 bps, No Parity, 8 Bits, 1 Stop Bit 115,200 bps, No Parity, 8 Bits, 1 Stop Bit115,200 bps, No Parity, 8 Bits, 1 Stop Bit 115,200 bps, No Parity, 8 Bits, 1 Stop Bit115,200 bps, No Parity, 8 Bits, 1 Stop Bit
Drive CapacityDrive Capacity Single 500GB 2.5 inch SATA HDD, internal, fixedSingle 500GB 2.5 inch SATA HDD, internal, fixed Single 1TB 3.5 inch, SATA HDD, internal, fixedSingle 1TB 3.5 inch, SATA HDD, internal, fixed 2x 600 GB HDD, RAID 1, 2.5 inch, FRU2x 600 GB HDD, RAID 1, 2.5 inch, FRU 2x 600 GB HDD, RAID 1, 2.5 inch, FRU2x 600 GB HDD, RAID 1, 2.5 inch, FRU 4x 900 GB HDD, RAID 10, 2.5 inch, FRU4x 900 GB HDD, RAID 10, 2.5 inch, FRU 4x 900 GB HDD, RAID 10, 2.5 inch, FRU4x 900 GB HDD, RAID 10, 2.5 inch, FRU 4x 800 GB SSD, RAID 10, 2.5 inch, FRU4x 800 GB SSD, RAID 10, 2.5 inch, FRU 4x 960 GB SSD, RAID 10, 2.5 inch, FRU4x 960 GB SSD, RAID 10, 2.5 inch, FRU
EnclosureEnclosure 1RU, Desktop formfactor1RU, Desktop formfactor 1RU, Fits 19 inch Rack1RU, Fits 19 inch Rack 1RU, Fits 19 inch Rack1RU, Fits 19 inch Rack 2RU, Fits 19 inch Rack2RU, Fits 19 inch Rack 2RU, Fits 19 inch Rack2RU, Fits 19 inch Rack 2RU, Fits 19 inch Rack2RU, Fits 19 inch Rack 2RU, Fits 19 inch Rack2RU, Fits 19 inch Rack 2RU, Fits 19 inch Rack2RU, Fits 19 inch Rack
Chassis Dimension WxDxHChassis Dimension WxDxH 11” x 6.9” x1.7”(280 x 175 x 43.2 mm)11” x 6.9” x1.7”(280 x 175 x 43.2 mm) 17.2” x 19.7” x 1.7”(437 x 500 x 43.2 mm)17.2” x 19.7” x 1.7”(437 x 500 x 43.2 mm) 17.2in(437mm) x 25.6in(650mm) x 1.7in(43.2mm)17.2in(437mm) x 25.6in(650mm) x 1.7in(43.2mm) 17.24in(438mm) x 24.41in(620mm) x 3.48in (88.4mm)17.24in(438mm) x 24.41in(620mm) x 3.48in (88.4mm) 17.24in(438mm) x 24.41in(620mm) x 3.48in(88.4mm)17.24in(438mm) x 24.41in(620mm) x 3.48in(88.4mm) 17.24in(438mm) x 24.41in(620mm) x 3.48in(88.4mm)17.24in(438mm) x 24.41in(620mm) x 3.48in(88.4mm) 17.2” x 27.9” x 3.5” (437 x 709 x 89 mm)17.2” x 27.9” x 3.5” (437 x 709 x 89 mm) 17.2” x 33.5” x 3.5” (437 x 851 x 89 mm)17.2” x 33.5” x 3.5” (437 x 851 x 89 mm)
AC Power SupplyAC Power Supply External 60 Watt 12V@5A Ouput AC Adapter, 90-264 VAC, 50-60 Hz, IEC60320-C14, inlet, FRUExternal 60 Watt 12V@5A Ouput AC Adapter, 90-264 VAC, 50-60 Hz, IEC60320-C14, inlet, FRU Single 250 watt, 90-264 VAC, 3.5 - 1.5 A, 50-60 Hz, IEC60320-C14, inlet,Internal, FixedSingle 250 watt, 90-264 VAC, 3.5 - 1.5 A, 50-60 Hz, IEC60320-C14, inlet,Internal, Fixed Redundant (1+1) 750 watt,100 - 240 VAC 9 – 4.5A, 50-60 Hz IEC60320 -C14 inlet, FRUeRedundant (1+1) 750 watt,100 - 240 VAC 9 – 4.5A, 50-60 Hz IEC60320 -C14 inlet, FRU Redundant (1+1) 800 watt, 100 - 240 VAC9 – 4.5A, 50-60 Hz IEC60320 -C14 inlet, FRUedundant (1+1) 800 watt, 100 - 240 VAC9 – 4.5A, 50-60 Hz IEC60320 -C14 inlet, FRU Redundant (1+1) 800 watt,100 - 240 VAC 9 – 4.5A, 50-60 Hz IEC60320 -C14 inlet, FRURedundant (1+1) 800 watt,100 - 240 VAC 9 – 4.5A, 50-60 Hz IEC60320 -C14 inlet, FRU Redundant (1+1) 800 watt, 100 - 240 VAC 10.5 – 4.0A, 50-60 Hz IEC60320-C14 inlet, FRURedundant (1+1) 800 watt, 100 - 240 VAC 10.5 – 4.0A, 50-60 Hz IEC60320-C14 inlet, FRU Redundant (1+1) 1200 watt, 100 - 140 VAC, 14.7 - 10.5 A 1400 watt, 180 - 240 VAC, 9.5 - 7.2 A, 50-60 Hz, FRU IEC60320 -C14 inlet, FRURedundant (1+1) 1200 watt, 100 - 140 VAC, 14.7 - 10.5 A 1400 watt, 180 - 240 VAC, 9.5 - 7.2 A, 50-60 Hz, FRU IEC60320 -C14 inlet, FRU Redundant (1+1) 800W: 100-127V, 9.8A-7A 1000W: 220-240V, 7-5A, 50-60Hz, FRU IEC60320-C14 inlet, FRURedundant (1+1) 800W: 100-127V, 9.8A-7A 1000W: 220-240V, 7-5A, 50-60Hz, FRU IEC60320-C14 inlet, FRU
Power Consumption Maximum (watts)Power Consumption Maximum (watts) 27 watts27 watts 85 watts85 watts 265 watts265 watts 426 watts426 watts 519 watts519 watts 658 watts658 watts 850 watts850 watts 760 watts760 watts
Thermal Dissipation Maximum (BTU/h)Thermal Dissipation Maximum (BTU/h) 92 BTU/h92 BTU/h 290 BTU/h290 BTU/h 904 BTU/h904 BTU/h 1454 BTU/h1454 BTU/h 1771 BTU/h1771 BTU/h 2245 BTU/h2245 BTU/h 2908 BTU/h2908 BTU/h 2594 BTU/h2594 BTU/h
MTBF(h)MTBF(h) 95,400 h95,400 h 56,400 h56,400 h 54,200 h54,200 h 31,640 h31,640 h 58,900 h58,900 h 52,469 h52,469 h 40,275 h40,275 h 36,101 h36,101 h
Appliance Alone / As Shipped Weight lb.(kg)Appliance Alone / As Shipped Weight lb.(kg) 3.75 lb (1.7 kg) / 6.5 lb (2.95 kg)3.75 lb (1.7 kg) / 6.5 lb (2.95 kg) 16.2 lb (7.3 kg) / 28.2 lb (2.95 kg)16.2 lb (7.3 kg) / 28.2 lb (2.95 kg) 29.8 lbs (13.5 kg) / 40.8 lbs (18.5 Kg)29.8 lbs (13.5 kg) / 40.8 lbs (18.5 Kg) 37.4 lbs (17.0 kg) / 58.6 lbs (26.6 kg)37.4 lbs (17.0 kg) / 58.6 lbs (26.6 kg) 42.4 lbs (19.2 kg) / 63.5 lbs (28.8 kg)42.4 lbs (19.2 kg) / 63.5 lbs (28.8 kg) 42.7 lbs (19.2 kg) / 63.8 lbs (29.0 kg)42.7 lbs (19.2 kg) / 63.8 lbs (29.0 kg) 51 lb. (23 kg) / 66 lb. (30 kg)51 lb. (23 kg) / 66 lb. (30 kg) 46 lb (21 kg) / 90 lb (40.2 kg)46 lb (21 kg) / 90 lb (40.2 kg)
Regulatory ComplianceRegulatory Compliance EN 60950-1, 1:2006 +A11 :2009 +A1:2010 +A12:2011 +A2:2013; IEC 60950- 1:2005 +Am 1:2009 +Am 2:2013EN 60950-1, 1:2006 +A11 :2009 +A1:2010 +A12:2011 +A2:2013; IEC 60950- 1:2005 +Am 1:2009 +Am 2:2013 EN 60950-1, 1:2006 +A11 :2009 +A1:2010 +A12:2011 +A2:2013; IEC 60950- 1:2005 +Am 1:2009 +Am 2:2013EN 60950-1, 1:2006 +A11 :2009 +A1:2010 +A12:2011 +A2:2013; IEC 60950- 1:2005 +Am 1:2009 +Am 2:2013 IEC 60950-1:2005 (Second Edition) +Am1:2009 +Am 2:2013 EN 60950-1:2006 +A11:2009 +A1:2010 +A12:2011 +A2:2013 CSA 60950-1-07, Second Edition CAN/CSA-C22.2 No 60950-1-07 +Am1:2011 +Am2:2014IEC 60950-1:2005 (Second Edition) +Am1:2009 +Am 2:2013 EN 60950-1:2006 +A11:2009 +A1:2010 +A12:2011 +A2:2013 CSA 60950-1-07, Second Edition CAN/CSA-C22.2 No 60950-1-07 +Am1:2011 +Am2:2014 IEC 60950-1:2005 (Second Edition) +Am1:2009 +Am 2:2013 EN 60950-1:2006 +A11:2009 +A1:2010 +A12:2011 +A2:2013 UL 60950 CAN/CSA-C22.2 No 60950-1-07, +Am.1:2011 +Am.2:2014 Information Technology Equipment - Safety - Part 1: General Requirements UL 60950-1-2014IEC 60950-1:2005 (Second Edition) +Am1:2009 +Am 2:2013 EN 60950-1:2006 +A11:2009 +A1:2010 +A12:2011 +A2:2013 UL 60950 CAN/CSA-C22.2 No 60950-1-07, +Am.1:2011 +Am.2:2014 Information Technology Equipment - Safety - Part 1: General Requirements UL 60950-1-2014 IEC 60950-1:2005 (Second Edition) + Am1:2009 + Am 2:2013 EN 60950-1:2006 +A11:2009 +A1:2010 +A12:2011 +A2:2013 UL 60950 CAN/CSA-C22.2 No 60950-1-07, +Am.1:2011 +Am.2:2014 Information Technology Equipment - Safety - Part 1: General Requirements UL 60950-1-2014IEC 60950 EN 60950 CSA 60950-00 CE Marking IEC 60950-1:2005 (Second Edition) +Am1:2009 +Am 2:2013 EN 60950-1:2006 +A11:2009 +A1:2010 +A12:2011 +A2:2013 UL 60950 CAN/CSA-C22.2 No 60950-1-07, +Am.1:2011 +Am.2:2014 Information Technology Equipment - Safety - Part 1: General Requirements UL 60950-1-2014IEC 60950-1:2005 (Second Edition) +Am1:2009 +Am 2:2013 EN 60950-1:2006 +A11:2009 +A1:2010 +A12:2011 +A2:2013 UL 60950 CAN/CSA-C22.2 No 60950-1-07, +Am.1:2011 +Am.2:2014 Information Technology Equipment - Safety - Part 1: General Requirements UL 60950-1-2014IEC 60950-1:2005 (Second Edition) +Am1:2009 +Am 2:2013 EN 60950-1:2006 +A11:2009 +A1:2010 +A12:2011 +A2:2013 UL 60950 CAN/CSA-C22.2 No 60950-1-07, +Am.1:2011 +Am.2:2014 Information Technology Equipment - Safety - Part 1: General Requirements UL 60950-1-2014 IEC 60950-1 EN 60950-1 CSA 60950-1 CE MarkingIEC 60950-1 EN 60950-1 CSA 60950-1 CE Marking UL 60950-1, CAN/ CSA C22.2 No. 60950-1-07, IEC 60950- 1:2005 +A1:2009 +A2:2013, AS/NSZ 60950.1-2011UL 60950-1, CAN/ CSA C22.2 No. 60950-1-07, IEC 60950- 1:2005 +A1:2009 +A2:2013, AS/NSZ 60950.1-2011
Regulatory Compliance EMCRegulatory Compliance FCC Part 15 SubPart B Class A; ICES-003 Class A; EN55022 Class A; VCCI V-3 Class A; EN 55024; EN 61000-3-2 Class A; EN 61000-3-3; CNS 13438 (2006) Class A; CISPR22 Class A; AS/NZS CISPR 22 Class A; KN 32; KN 35FCC Part 15 SubPart B Class A; ICES-003 Class A; EN55022 Class A; VCCI V-3 Class A; EN 55024; EN 61000-3-2 Class A; EN 61000-3-3; CNS 13438 (2006) Class A; CISPR22 Class A; AS/NZS CISPR 22 Class A; KN 32; KN 35FCC (Part 15 Class-A), CE (Class-A), CNS, AS/NZS, VCCI(Class A) FCC Part 15 SubPart B Class A; ICES-003 Class A; EN55022 Class A; VCCI V-3 Class A; EN 55024; EN 61000-3-2 Class A; EN 61000-3-3; CNS 13438 (2006) Class A; CISPR22 Class A; AS/NZS CISPR 22 Class A; KN 32; KN 35FCC Part 15 SubPart B Class A; ICES-003 Class A; EN55022 Class A; VCCI V-3 Class A; EN 55024; EN 61000-3-2 Class A; EN 61000-3-3; CNS 13438 (2006) Class A; CISPR22 Class A; AS/NZS CISPR 22 Class A; KN 32; KN 35FCC (Part 15 Class-A), CE (Class-A), CNS, AS/NZS, VCCI(Class A) FCC Part 15 SubPart B Class A; ICES-003 Class A; EN55022 Class A; VCCI V-3 Class A; EN 55024; EN 61000-3-2 Class A; EN 61000-3-3; CNS 13438 (2006) Class A; CISPR22 Class A; AS/NZS CISPR 22 Class A; KN 32; KN 35FCC Part 15 SubPart B Class A; ICES-003 Class A; EN55022 Class A; VCCI V-3 Class A; EN 55024; EN 61000-3-2 Class A; EN 61000-3-3; CNS 13438 (2006) Class A; CISPR22 Class A; AS/NZS CISPR 22 Class A; KN 32; KN 35 FCC Part 15 SubPart B Class A; ICES-003 ClassA; EN 61000-3-2 Class A; EN 61000-3-3; CISPR22 Class AFCC Part 15 SubPart B Class A; ICES-003 ClassA; EN 61000-3-2 Class A; EN 61000-3-3; CISPR22 Class A FCC Part 15 SubPart B Class A; ICES-003 Class A; EN 61000-3-2 Class A; EN 61000-3-3; CISPR22 Class AFCC Part 15 SubPart B Class A; ICES-003 Class A; EN 61000-3-2 Class A; EN 61000-3-3; CISPR22 Class A FCC Part 15 SubPart B Class A; ICES-003 Class A; EN 61000-3-2 Class A; EN 61000-3-3; CISPR22 Class AFCC Part 15 SubPart B Class A; ICES-003 Class A; EN 61000-3-2 Class A; EN 61000-3-3; CISPR22 Class A FCC (Part 15 Class-A), CE (Class-A), CNS, AS/NZS, VCCI(Class A)FCC (Part 15 Class-A), CE (Class-A), CNS, AS/NZS, VCCI(Class A)> FCC Part 15SubPart B Class A, ICES-003 Class A, EN55022 Class A, VCCI V-3 Class A,EN 55024, EN61000-3-2 Class A, EN 61000-3-3, CNS 13438 (2006) Class A, CISPR22 Class A, AS/NZS CISPR 22 Class ACC Part 15SubPart B Class A, ICES-003 Class A, EN55022 Class A, VCCI V-3 Class A,EN 55024, EN61000-3-2 Class A, EN 61000-3-3, CNS 13438 (2006) Class A, CISPR22 Class A, AS/NZS CISPR 22 Class A
Safety CertificationsSafety Certifications -- -- -- -- -- -- CC NDPP v1.1CC NDPP v1.1 UL 60950-1,CAN/CSA C22.2 No. 60950-1-07, IEC6060950-1:2005 +A1:2009+ A2:2013, AS/NSZ 60950.1-2011UL 60950-1,CAN/CSA C22.2 No. 60950-1-07, IEC6060950-1:2005 +A1:2009+ A2:2013, AS/NSZ 60950.1-2011
Environmental ComplianceRegulatory Compliance RoHS, REACH, WEEERoHS, REACH, WEEE RoHS, REACH, WEEERoHS, REACH, WEEE RoHS, REACH, WEEERoHS, REACH, WEEE RoHS, REACH, WEEERoHS, REACH, WEEE RoHS, REACH, WEEERoHS, REACH, WEEE RoHS, REACH, WEEERoHS, REACH, WEEE RoHS, REACH, WEEERoHS, REACH, WEEE RoHS, REACH, WEEERoHS, REACH, WEEE
Operating TemperatureOperating Temperature 0° C to 40° C0° C to 40° C 0° C to 40° C0° C to 40° C 0 ~ 35° C (32 ~ 95° F)0 ~ 35° C (32 ~ 95° F) 0 ~ 35° C (32 ~ 95° F)0 ~ 35° C (32 ~ 95° F) 0 ~ 35° C (32 ~ 95° F)0 ~ 35° C (32 ~ 95° F) 0 ~ 35° C (32 ~ 95° F)0 ~ 35° C (32 ~ 95° F) 10°C to 35°C Tested from 0°C to 40°C for additional margin10°C to 35°C Tested from 0°C to 40°C for additional margin 10°C to 35°C Tested from 0°C to 40°C for additional margin10°C to 35°C Tested from 0°C to 40°C for additional margin
Non-Operating TemperatureNon-Operating Temperature -20°C to 80°C-20°C to 80°C -20°C to 80°C-20°C to 80°C -40°C to 70°C-40°C to 70°C -40°C to 70°C-40°C to 70°C -40°C to 70°C-40°C to 70°C -40°C to 70°C-40°C to 70°C -40°C to 70°C-40°C to 70°C -40°C to 70°C-40°C to 70°C
Operating Relative HumidityOperating Relative Humidity 5% - 85% (non-condensing)5% - 85% (non-condensing) 5% - 85% (no-ncondensing)5% - 85% (non-condensing) 10 ~ 95% @ 40° C, non-condensing10 ~ 95% @ 40° C, non-condensing 10 ~ 95% @ 40° C, non-condensing10 ~ 95% @ 40° C, non-condensing 10 ~ 95% @ 40° C, non-condensing10 ~ 95% @ 40° C, non-condensing 10 ~ 95% @ 40° C, non-condensing10 ~ 95% @ 40° C, non-condensing 10% - 85% (non-condensing)10% - 85% (non-condensing) 10% - 85% (non-condensing)10% - 85% (non-condensing)
Non- Operating Relative HumidityNon- Operating Relative Humidity 5% - 95% (non- condensing)5% - 95% (non-condensing) 5% - 95% (non- condensing)5% - 95% (non-condensing) 5% - 95% (non- condensing)5% - 95% (non-condensing) 5% - 95% (non- condensing)5% - 95% (non-condensing) 5% - 95% (non- condensing)5% - 95% (non-condensing) 5% - 95% (non- condensing)5% - 95% (non-condensing) 5% - 95% (non- condensing)5% - 95% (non-condensing) 5% - 95% (non- condensing)5% - 95% (non-condensing)
Operating AltitudeOperating Altitude 5.000 ft5.000 ft 5.000 ft5.000 ft 5.000 ft5.000 ft 5.000 ft5.000 ft 5.000 ft5.000 ft 5.000 ft5.000 ft 5.000 ft5.000 ft 5.000 ft5.000 ft

FireEye Network Smart Node IPS, Physical Specifications

NX 1500 NX 2500 NX 2550 NX 3500 NX 4500 NX 5500 NX 10450 NX 10550
Max IPS PerformanceMax IPS Performance Up to 50 MbpsUp to 50 Mbps Up to 100 / 250 MbpsUp to 100 / 250 Mbps Up to 500 MbpsUp to 500 Mbps Up to 1 GbpsUp to 1 Gbps Up to 2 GbpsUp to 2 Gbps Up to 5 GbpsUp to 5 Gbps Up to 8 GbpsUp to 8 Gbps Up to 8 GbpsUp to 8 Gbps
Max Concurrent Connections Max Concurrent Connections 15K 15K 80K 80K 160K 160K 500K 500K 1M 1M 2M 2M 4M 4M 4M 4M
New Connections Per SecondNew Connections Per Second 750/Sec750/Sec 4K/Sec4K/Sec 8K/Sec8K/Sec 10K/Sec10K/Sec 20K/Sec20K/Sec 40K/Sec40K/Sec 80K/Sec80K/Sec 80K/Sec80K/Sec

FireEye Network Smart Node, Virtual Specifications

NXS 1500V NXS 2500V NXS 2550V NXS 4500V NXS 6500V
User CountUser Count 500500 1,0001,000 2,5002,500 5,0005,000 10,00010,000
OS Support OS Support Microsoft Windows Mac OS X Microsoft Windows Mac OS X Microsoft Windows Mac OS X Microsoft Windows Mac OS X Microsoft Windows Mac OS X Microsoft Windows Mac OS X Microsoft Windows Mac OS X Microsoft Windows Mac OS X Microsoft Windows Mac OS X Microsoft Windows Mac OS X
Performance* Performance* Up to 50 Mbps Up to 50 Mbps Up to 100 Mbps Up to 100 Mbps Up to 250 Mbps Up to 250 Mbps Up to 500 Mbps Up to 500 Mbps Up to 1 Gbps Up to 1 Gbps
Network Monitoring PortsNetwork Monitoring Ports 1-81-8 1-81-8 1-81-8 1-81-8 1-81-8
Network Management PortsNetwork Management Ports 1 or 21 or 2 1 or 21 or 2 1 or 21 or 2 1 or 21 or 2 1 or 21 or 2
Network Ports Mode of OperationNetwork Ports Mode of Operation Inline, SPANInline, SPAN Inline, SPANInline, SPAN Inline, SPANInline, SPAN Inline, SPANInline, SPAN Inline, SPANInline, SPAN
CPU CoresCPU Cores 33 66 88 88 1616
MemoryMemory 10 GB10 GB 16 GB16 GB 16 GB16 GB 32 GB32 GB 32 GB32 GB
Drive CapacityDrive Capacity 384 GB384 GB 384 GB384 GB 384 GB384 GB 512 GB512 GB 512 GB512 GB
Network AdaptersNetwork Adapters VMXNet 3, vNICVMXNet 3, vNIC VMXNet 3, vNICVMXNet 3, vNIC VMXNet 3, vNICVMXNet 3, vNIC VMXNet 3, vNICVMXNet 3, vNIC VMXNet 3, vNICVMXNet 3, vNIC
Hypervisor SupportHypervisor Support VMWare ESXi 6.0 or laterVMWare ESXi 6.0 or later VMWare ESXi 6.0 or laterVMWare ESXi 6.0 or later VMWare ESXi 6.0 or laterVMWare ESXi 6.0 or later VMWare ESXi 6.0 or laterVMWare ESXi 6.0 or later VMWare ESXi 6.0 or laterVMWare ESXi 6.0 or later

FireEye Network Smart Node IPS, Virtual Specifications

NXS 1500V NXS 2500V NXS 2550V NXS 4500V NXS 6500V
Max IPS PerformanceMax IPS Performance Up to 50 MbpsUp to 50 Mbps Up to 100 MbpsUp to 100 Mbps Up to 250 MbpsUp to 250 Mbps Up to 500 MbpsUp to 500 Mbps Up to 1 GbpsUp to 1 Gbps
Max Concurrent Connections Max Concurrent Connections 15K 15K 80K 80K 80K 80K 160K 160K 500K 500K
New Connections Per SecondNew Connections Per Second 750/Sec750/Sec 4K/Sec4K/Sec 4K/Sec4K/Sec 8K/Sec8K/Sec 10K/Sec10K/Sec

FireEye MVX Smart Grid Specifications

VX 5500 VX 12500
OS SupportOS Support Microsoft Windows Mac OS X Microsoft Windows Mac OS X Microsoft Windows Microsoft Windows
Performance*Performance* Up to 2 GbpsUp to 2 Gbps Up to 10 GbpsUp to 10 Gbps
High Availability* High Availability* N+1 N+1 N+1 N+1
Management Ports (rear panel)Management Ports (rear panel) 1x 10/100/1000 BASE- T Ports1x 10/100/1000 BASE- T Ports 1x 10/100/1000 BASE- T Ports1x 10/100/1000 BASE- T Ports
High Availability (HA) Ports (rear panel) High Availability (HA) Ports (rear panel) Not Available Not Available Not Available Not Available
Cluster Ports (rear panel)Cluster Ports (rear panel) 3x 10/100/1000 BASE- T Ports3x 10/100/1000 BASE- T Ports 2x 10/ 100/1000 BASE-T Ports, 2x 1000/10G BASE-T Ports2x 10/ 100/1000 BASE-T Ports, 2x 1000/10G BASE-T Ports
IPMI Port (rear panel)IPMI Port (rear panel) IncludedIncluded IncludedIncluded
Front LCD & KeypadFront LCD & Keypad Not AvailableIncluded IncludedIncluded
PS/2 Keyboard and Mouse, DB15 VGA Ports (rear panel) PS/2 Keyboard and Mouse, DB15 VGA Ports (rear panel) Not AvailableIncluded IncludedIncluded
USB Ports (rear panel) USB Ports (rear panel) 4x Type A USB Ports4x Type A USB Ports 2x Type A USB Ports2x Type A USB Ports
Serial Port (rear panel)Serial Port (rear panel) 115,200 bps, No Parity, 8 Bits, 1 Stop Bit 115,200 bps, No Parity, 8 Bits, 1 Stop Bit 115,200 bps, No Parity, 8 Bits, 1 Stop Bit115,200 bps, No Parity, 8 Bits, 1 Stop Bit
Drive CapacityDrive Capacity 2x 2TB 3.5 SAS HDD, RAID 1, hot-swappable, FRU2x 2TB 3.5 SAS HDD, RAID 1, hot-swappable, FRU 4 x 900GB HDD, RAID 10, 2.5 inch, FRU4 x 900GB HDD, RAID 10, 2.5 inch, FRU
EnclosureEnclosure 1RU, Fits 19 inch Rack1RU, Fits 19 inch Rack 1RU, Fits 19 inch Rack1RU, Fits 19 inch Rack
Chassis Dimension WxDxHChassis Dimension WxDxH 17.2x25.6x1.7 (437 x 650 x 43.2 mm)17.2x25.6x1.7 (437 x 650 x 43.2 mm) 17.2x25.6x1.7 (437 x 650 x 43.2 mm)17.2x25.6x1.7 (437 x 650 x 43.2 mm)
DC Power SupplyDC Power Supply Not AvailableNot Available Not AvailableNot Available
AC Power SupplyAC Power Supply Redundant (1+1) 750 watt, 100-240 VAC, 8 - 3.8 A, 50-60 Hz, IEC60320-C14, inlet, hot-swappable, FRURedundant (1+1) 750 watt, 100-240 VAC, 8 - 3.8 A, 50-60 Hz, IEC60320-C14, inlet, hot-swappable, FRU Redundant (1+1) 800W: 100-127V, 9.8A-7A 1000W: 220-240V, 7-5A, 50-60Hz, FRU IEC60320-C14 inlet, FRURedundant (1+1) 800W: 100-127V, 9.8A-7A 1000W: 220-240V, 7-5A, 50-60Hz, FRU IEC60320-C14 inlet, FRU
Power Consumption Maximum (watts)Power Consumption Maximum (watts) 285 watts285 watts 760 watts760 watts
Thermal Dissipation Maximum (BTU/h)hermal Dissipation Maximum (BTU/h) 972 BTU/h972 BTU/h 2594 BTU/h2594 BTU/h
VX 5500 VX 12500
MTBF(h)MTBF(h) 54,200 h54,200 h 38,836 h38,836 h
Appliance Alone / As Shipped Weight lb.(kg)Appliance Alone / As Shipped Weight lb.(kg) 33 lb (15 kg) / 48 lb (21.8 kg)33 lb (15 kg) / 48 lb (21.8 kg) 46 lb (21 kg) / 90 lb (40.2 kg)46 lb (21 kg) / 90 lb (40.2 kg)
Regulatory Compliance SafetyRegulatory Compliance Safety UL 60950-1-2014; CAN/CSA C22.2 No. 60950-1-07, Am.1:2011+Am.2:2014; AS/NSZ 60950.1- 2011UL 60950-1-2014; CAN/CSA C22.2 No. 60950-1-07, Am.1:2011+Am.2:2014; AS/NSZ 60950.1- 2011 UL 60950-1 CAN/CSA C22.2 No. 60950-1-07 IEC 60950-1:2005+A1:2009+A2:2013 AS/NSZ 60950.1-2011UL 60950-1 CAN/CSA C22.2 No. 60950-1-07 IEC 60950-1:2005+A1:2009+A2:2013 AS/NSZ 60950.1-2011
Regulatory Compliance EMCRegulatory Compliance FCC Part 15 SubPart B Class A; ICES-003 Class A; EN55022 Class A; VCCI V-3 Class A; EN 55024; EN 61000-3-2 Class A; EN 61000-3-3; CNS 13438 (2006) Class A; CISPR22 Class A; AS/NZS CISPR 22 Class A; KN 32; KN 35FCC Part 15 SubPart B Class A; ICES-003 Class A; EN55022 Class A; VCCI V-3 Class A; EN 55024; EN 61000-3-2 Class A; EN 61000-3-3; CNS 13438 (2006) Class A; CISPR22 Class A; AS/NZS CISPR 22 Class A; KN 32; KN 35 FFCC Part 15 SubPart B Class A ICES-003 Class A EN 55022 Class A VCCI V-3 Class A EN 55024 EN 61000-3-2 Class A EN 61000-3-3 CNS 13438 (2006) Class A CISPR22 Class A AS/NZS CISPR 22 Class AFFCC Part 15 SubPart B Class A ICES-003 Class A EN 55022 Class A VCCI V-3 Class A EN 55024 EN 61000-3-2 Class A EN 61000-3-3 CNS 13438 (2006) Class A CISPR22 Class A AS/NZS CISPR 22 Class A
Environmental ComplianceRegulatory Compliance RoHS, REACH, WEEERoHS, REACH, WEEE RoHS, REACH, WEEE Conflict MineralsRoHS, REACH, WEEE Conflict Minerals
Operating TemperatureOperating Temperature 0° C to 40° C0° C to 40° C 10°C to 35°C Tested from 0°C to 40°C for additional margin10°C to 35°C Tested from 0°C to 40°C for additional margin
Non-Operating TemperatureNon-Operating Temperature -40°C to 70°C-40°C to 70°C -40°C to 70°C-40°C to 70°C
Operating Relative HumidityOperating Relative Humidity 10% - 85% (non-condensing)10% - 85% (non-condensing) 10% - 85% (non-condensing)10% - 85% (non-condensing)
Non-Operating Relative HumidityNon- Operating Relative Humidity 5% - 95% (non-condensing)5% - 95% (non-condensing) 5% - 95% (non-condensing)5% - 95% (non-condensing)
Operating AltitudeOperating Altitude 5,000 ft5,000 ft 5,000 ft5,000 ft

FireEye Active Fail Open Switch Specifications

AFO 10G Switch
Dimensions (WxDxH)Dimensions (WxDxH) 8.75 x 12.4 x 1.31 in.8.75 x 12.4 x 1.31 in.
Management Ports Management Ports (1) DB9 Serial Console, (1) RJ45 Cat5e Port (10/100) (1) DB9 Serial Console, (1) RJ45 Cat5e Port (10/100)
Network PortsNetwork Ports (1) Quad LC Connector(1) Quad LC Connector
Monitoring PortsMonitoring Ports (2) XFP Ports(2) XFP Ports
AC Power InputAC Power Input 100 ~ 240 VAC, .5 A, 47-63 Hz100 ~ 240 VAC, .5 A, 47-63 Hz
Operating TempOperating Temp 0° C to 40° C0° C to 40° C
* All performance values vary depending on the system configuration and traffic profile being processed.
** With appropriate redundant hardware configurations.


Support Services

FireEye offers simple and flexible support programs to maximize the value of your FireEye products and services. Four different levels of support services are available: Platinum, Platinum Priority Plus, Government and Government Priority Plus. For more information about FireEye support, refer to FireEye Support services.